- Inhibitors
- Antibodies
- Compound Libraries
- New Products
- Contact Us
research use only
2x SYBR Green qPCR master mix utilizes a special performance-enhanced Taq DNA polymerase protected via a hot-start activation technique, and optimized qPCR buffer system to perform SYBR Green I based quantitative PCR.
Selleck's Has Been Cited by 848 Publications
High Sensitivity: Lower Ct values ensure higher efficiency of amplification
Cost Effective: Offered at much discounted price compared to market price
Higher amplification efficiency and stronger fluorescence signal
Using the same cDNA template and primers to amplify GAPDH, Selleck 2x SYBR Green QPCR Master Mix amplified faster with stronger fluorescence signal and better amplification efficiency than other brands.
Accurate quantitation and high stability
Using the same cDNA template and primers to amplify RPL37, Selleck 2x SYBR Green QPCR Master Mix shows accurate quantitation with high stability.
Higher specificity and sensitivity
Failure to amplify low-copy targets can be due to lack of sensitivity and/or specificity. Selleck 2x SYBR Green QPCR Master Mix uses a new type of hot-start enzyme which reduces non-specific amplification at low temperature, improving amplification of low-copy genes.
| Ct ValueGene | Selleck | Vazyme | Yeasen | Kapa | Takara | TIANGEN | NEB | TransGen |
| GAPDH (Human) | 19.01 | 20.34 | 18.84 | 19.35 | 19.32 | 19.08 | 19.54 | 19.9 |
| Actin (Human) | 18.5 | 20.07 | 19 | 18.71 | 19.9 | 19.4 | 23.64 | 19.86 |
| Vim (Human) | 18.55 | 20.19 | 18.56 | 18.82 | 19.9 | 19.11 | 19.27 | 19.83 |
| IL-6 (Human, low Copy) | 29.03 | 29.55 | 32.54 | 27.56 | 35.12 | 33.31 | 33.02 | 29.54 |
| GAPDH (Mouse) | 20.2 | 21.37 | 20.39 | 21.34 | 20.83 | 20.67 | 21.01 | 21.85 |
| GAPDH (Mouse) | 20.2 | 21.37 | 20.39 | 21.34 | 20.83 | 20.67 | 21.01 | 21.85 |
| RPL37 (Mouse) | 18.76 | 19.69 | 18.77 | 18.77 | 19.3 | 19.14 | 19.3 | 19.86 |
2x SYBR Green qPCR master mix utilizes a special performance-enhanced Taq DNA polymerase protected via a hot-start activation technique, and optimized qPCR buffer system to perform SYBR Green I based quantitative PCR. The mix, prepared at 2x reaction concentration, can be directly used for robust and low-template quantitative PCR with high sensitivity, specificity and reliability.
| Component | Cat#: B21202 | Cat#: B21203 |
|---|---|---|
| 2x SYBR Green qPCR Master Mix * | 5 mL (for 200 reactions with 50 μl/rxn for 500 reactions with 20 μl/rxn for 1000 reactions with 10 μl/rxn) |
25 mL (for 1000 reactions with 50 μl/rxn for 2500 reactions with 20 μl/rxn for 5000 reactions with 10 μl/rxn) |
| 50x ROX Dye (low conc.) | 200 μL | 1000 μL |
| 50x ROX Dye (high conc.) | 200 μL | 1000 μL |
| * Contains hot-start DNA Polymerase, dNTPs, Mg2+, and SYBR Green I dye | ||
| Instruments Requiring No ROX Reference Dye | Bio-Rad: CFX96™, CFX384™, iCycler iQ™, iQ™5, MyiQ™, Opticon®, Opticon 2, Chromo4™, MiniOpticon™; Cepheid: SmartCycler®; Eppendorf: Mastercycler® eprealplex, realplex 2s; Illumina: Eco™ qPCR; Qiagen/Corbett: Rotor-Gene® Q, Rotor-Gene® 3000, Rotor-Gene® 6000; Roche: LightCycler® 480, 96, Nano, 1.5/2.0**; Thermo Scientific: PikoReal Cycler |
|---|---|
| Instruments Requiring ROX Reference Dye 1 (High Concentration) | Applied Biosystems: 5700, 7000, 7300, 7700, 7900, 7900HT, 7900HT Fast; Applied Biosystems: StepOne™, StepOne Plus™ |
| Instruments Requiring ROX Reference Dye 2 (Low Concentration) | Applied Biosystems: 7500, 7500 Fast, Viia™7, QuantStudio 6 and 7 Flex System, QuantStudio 3 and 5; Agilent Stratagene: MX4000™, MX3005P™, MX3000P™ |
Store at -20°C for up to 2 years. Repetitive freeze-thaw cycles should be avoided. It is recommended to pre-aliquot the mix into small batches for frequent usage. Product quality is guaranteed under proper storage conditions.
If you have any other enquiries, please leave a message.