Onvansertib (NMS-P937)

Catalog No.S7255 Batch:S725505

Print

Technical Data

Formula

C24H27F3N8O3

Molecular Weight 532.52 CAS No. 1034616-18-6
Solubility (25°C)* In vitro DMSO 50 mg/mL (93.89 mM)
Ethanol 2 mg/mL (3.75 mM)
Water Insoluble
* <1 mg/ml means slightly soluble or insoluble.
* Please note that Selleck tests the solubility of all compounds in-house, and the actual solubility may differ slightly from published values. This is normal and is due to slight batch-to-batch variations.
* Room temperature shipping (Stability testing shows this product can be shipped without any cooling measures.)

Preparing Stock Solutions

Biological Activity

Description Onvansertib (NMS-P937, PCM-075, NMS1286937) is an orally available, selective Polo-like Kinase 1 (PLK1) inhibitor with IC50 of 2 nM, 5000-fold selectivity over PLK2/PLK3. Onvansertib (NMS-P937) potently causes a mitotic cell-cycle arrest followed by apoptosis in cancer cell lines and inhibits tumor growth. Phase 1.
Targets
PLK1 [1]
2 nM
In vitro

NMS-P937 shows a broad-spectrum antiproliferative activity against different solid tumor, leukemias and lymphomas cell lines. NMS-P937 potently causes a mitotic cell-cycle arrest followed by apoptosis in A2780 cells. [2]

In vivo

In mice xenografted with human HCT116 colon adenocarcinoma cells, NMS-P937 (90 mg/kg/d i.v. or p.o.) shows a significant tumor growth inhibition. [1]

In mice bearing HT29, Colo205 colorectal, or A2780 ovarian xenograft tumors, NMS-P937 inhibits xenograft tumor growth. In addition, NMS-P937, in combination with approved cytotoxic drugs, causes enhanced tumor regression, and prolongs survival of animals. [2]

Protocol (from reference)

Kinase Assay:

[1]

  • Kinase profile

    The inhibitory activity of putative kinase inhibitors and the potency of selected compounds are determined using a trans-phosphorylation assay. Specific peptide or protein substrates are trans-phosphorylated by their specific serine-threonine or tyrosine kinase, in the presence of ATP traced with 33P-γ-ATP, at optimized buffer and cofactors conditions. At the end of the phosphorylation reaction, more than 98% unlabeled ATP and radioactive ATP is captured by adding an excess of the ion exchange dowex resin; the resin then settles down to the bottom of the reaction plate by gravity. Supernatant, containing the phosphorylated substrate, is subsequently withdrawn and transferred into a counting plate, followed by evaluation by b-counting. Inhibitory potency evaluation for all the tested kinases was performed at 25 °C using a 60 min end-point assay where the concentrations of ATP and substrates are kept equal to 2 x αKm and saturated (>5 x αKm), respectively.

Cell Assay:

[2]

  • Cell lines

    137 solid tumor cell lines, and 43 cell lines derived from leukemias and lymphomas

  • Concentrations

    ~10 μM

  • Incubation Time

    72 hours

  • Method

    Cells are seeded into 96- or 384-well plates at densities ranging from 10,000 to 30,000/cm2 for adherent and 100,000/mL for nonadherent cells in appropriate medium supplemented with 10% fetal calf serum. After 24 hours, cells were treated in duplicate with serial dilutions of NMS-P937, and 72 hours later, the viable cell number was assessed by the CellTiter-Glo Assay (Promega). IC50 values were calculated with a sigmoidal fitting algorithm (Assay Explorer MDL). Experiments were carried out independently at least twice.

Selleck's Onvansertib (NMS-P937) has been cited by 12 publications

Genome-wide CRISPR screens identify PKMYT1 as a therapeutic target in pancreatic ductal adenocarcinoma [ EMBO Mol Med, 2024, 10.1038/s44321-024-00060-y] PubMed: 38570712
Therapeutic targeting of PLK1 in TERT promoter-mutant hepatocellular carcinoma [ Clin Transl Med, 2024, 14(5):e1703] PubMed: 38769666
Therapeutic targeting of PLK1 in TERT promoter-mutant hepatocellular carcinoma [ Clin Transl Med, 2024, 14(5):e1703] PubMed: 38769666
Proteomic analysis reveals a PLK1-dependent G2/M degradation program and a role for AKAP2 in coordinating the mitotic cytoskeleton [ Cell Rep, 2024, 43(8):114510] PubMed: 39018246
Onvansertib inhibits the proliferation and improves the cisplatin-resistance of lung adenocarcinoma via β-catenin/c-Myc signaling pathway [ Am J Cancer Res, 2023, 13(2):623-637] PubMed: 36895968
CSE1L is a negative regulator of the RB-DREAM pathway in p53 wild-type NSCLC and can be targeted using an HDAC1/2 inhibitor [ Sci Rep, 2023, 13(1):16271] PubMed: 37759078
CSE1L is a negative regulator of the RB-DREAM pathway in p53 wild-type NSCLC and can be targeted using an HDAC1/2 inhibitor [ Sci Rep, 2023, 13(1):16271] PubMed: 37759078
Development of a nanoparticle-based immunotherapy targeting PD-L1 and PLK1 for lung cancer treatment [ Nat Commun, 2022, 13(1):4261] PubMed: 35871223
Development of a nanoparticle-based immunotherapy targeting PD-L1 and PLK1 for lung cancer treatment [ Nat Commun, 2022, 13(1):4261] PubMed: 35871223
The Polo-like kinase 1 inhibitor onvansertib represents a relevant treatment for head and neck squamous cell carcinoma resistant to cisplatin and radiotherapy [ Theranostics, 2021, 11(19):9571-9586] PubMed: 34646387

RETURN POLICY
Selleck Chemical’s Unconditional Return Policy ensures a smooth online shopping experience for our customers. If you are in any way unsatisfied with your purchase, you may return any item(s) within 7 days of receiving it. In the event of product quality issues, either protocol related or product related problems, you may return any item(s) within 365 days from the original purchase date. Please follow the instructions below when returning products.

SHIPPING AND STORAGE
Selleck products are transported at room temperature. If you receive the product at room temperature, please rest assured, the Selleck Quality Inspection Department has conducted experiments to verify that the normal temperature placement of one month will not affect the biological activity of powder products. After collecting, please store the product according to the requirements described in the datasheet. Most Selleck products are stable under the recommended conditions.